Classical Complement Pathway, Pig, Assay
The HIT430 measures the classical pathway activity mediated via IgM. Complement deficiencies or other defects in the complement system can easily be screened by running an assay for each pathway in parallel or separately. The ELISA contains a positive control which can be used as process control to ensure that the classical complement cascade has run completely. This positive control cannot be used to determine the level of activation between batches. We advise to include in your study your own reference sample for 100% complement activity and negative control (eg non-preserved activated serum) to determine the level of activation of your samples. Beware that complement activity levels are strain dependent and might be affected by the way the samples are collected and processed.
The innate immune system is important in the first defense against foreign pathogens. A major component of this response is the complement system. The complement system consist of a complex family of proteins and receptors which are found in the circulation, in tissues and other body-fluids. Nowadays, also several links to the adaptive immunity are described. The system consist of three defined pathways which are activated by a pathway specific panel of molecules. Complement activation proceeds in a sequential fashion through the proteolytic cleavage of a series of proteins leading to the generation of activated products that mediate various biological activities through their interaction with specific cellular receptors and other serum proteins The three pathways, designated classical, lectin and alternative pathway, converge at a central component into a final common pathway. That is activation of C3 leading to formation of C3a and C3b. This cleavage activates the terminal complement pathway leading to eventually the formation of the terminal C5b-9 complement complex (TCC). The classical pathway is initiated by binding of C1q to antibody complexes, whereas the alternative and lectin pathway are activated in an antibody-independent fashion through the interaction of complement components with respectively specific carbohydrate groups and lipopolysaccharides (LPS) on the surface of foreign pathogens. The alternative pathway also acts as an amplification loop of the other pathways.
Under certain conditions, the complement system can be unfavorable to the host leading to e.g. autoimmune diseases and infections. Deficiency of C3 is e.g. associated with SLE. Alterations in the alternative pathway, like properdin or ficolin deficiency, increase the susceptibility to infection. Mannose binding lectin (MBL), a major component of the lectin pathway, is associated with bacterial, fungal and viral infection. A common way to measure the activity of the classical or alternative pathway is the haemolysis of erythrocytes. Furthermore some assays have been described to measure the activity of the MBL pathway. Not all assay are easy to perform. The pig pathway ELISAs are easy to use and specific per pathway by making use of a combination of specialized coatings and buffers. Complement deficiencies or other defects in the complement system can easily be screened by running an assay for each pathway in parallel or separately.
You may also like…
You may be interested in…
Calculate your ELISA data easily
With the ELISA calculator you can easily calculate ELISA data. Assayfit Pro helps to perform curve fitting. The calculator generates advanced reports, fit graph, fit parameters and goodness of fit are shown.
Latest Hycult Biotech news
- Discover Cross-Reactive Complement ELISA for NHP ResearchBridging Human and NHP Complement Research. At Hycult Biotech, we understand the importance of testing therapeutic agents on non-human primates (NHP) samples in order to get approval to enter clinical phases. That is why we have committed to the following initiative: Testing our existing complement ELISA assays for NHP research. Why Non Human Primate Samples… Read more: Discover Cross-Reactive Complement ELISA for NHP Research
- New Human Complement Pathway AssaysWe are very proud of our newly developed human classical and alternative complement pathway assays. They are produced in response to a growing demand for quantitative investigation of complement inhibitors or regulators at lower sample dilutions. This development aims to address the issue of false negative results, enabling more accurate and reliable analysis of complement… Read more: New Human Complement Pathway Assays
- Navigating the pitfalls in complement analysisOur colleague Erik Toonen shared his experience on how to analyze complement at the Complement-based Drug Development Summit in Boston in September 11-13th, 2023. He showed valuable insights on analyzing complements. For accurate complement analysis, it is important that not only the correct technique is used but also that pre-analytical sample handling is performed in… Read more: Navigating the pitfalls in complement analysis