Properdin, Human, ELISA kit

Quantity:
2 x 96 det.
Catalog #:
HK334-02

Original supplier of innate immunity products since 1994.

Our commitment to quality: Read more!

Contact our support team for more product information.

Can't find your application for a product? Request a sample!

Properdin, or factor P, is a single-chain plasma glycoprotein (apparent molecular mass 52-55 kDa), consisting of six thrombospondin repeat sequences between short N- and C-terminal domains. In the blood it exists as a mixture of head-to-tail dimers, trimers and tetramers, with a preponderance of trimers.
The protein is produced by a variety of leukocytes, including monocytes, T lymphocytes and neutrophils , but also by endothelial cells in which properdin synthesis and release are induced by shear stress.
Properdin participates in the alternative pathway of complement activation together with C3 and factors B, D, I and H. It stabilizes the labile C3bBb which is deposited on immune complexes or foreign surfaces. This permits amplification of C3bBb formation in competition with catabolism of C3b by factor I, which uses factor H as a cofactor. The local amplification process leads to the creation of the alternative pathway C5 convertase, C3bBb3b, and initiates the terminal pathway of complement activation.
Properdin prolongs the half-life of surface-bound C3bBb from 1½ minute to about 18 minutes. This is due to several effects: inhibition of C3b cleavage by factor I, increased affinity for factor B and inhibition of the dissociation of C3bBb into C3b and Bb. Properdin is consumed by binding to C3bBb, this binding showing an order of preference of tetramers over trimers over dimers, which is also the order of functional activity of the oligomeric forms.
Deficiency or malfunction of the molecule may lead to severe impairment of alternative pathway activation, depending on the precise nature of the defect. One parameter of functional defect in the presence of measurable levels of protein is an impaired generation of the more active tetramer and trimer forms.
The properdin gene is located on the short arm of the X chromosome, and congenital properdin deficiencies are therefore inherited as typical X-linked recessive traits.
Three types of familial deficiency have been described: type 1 (or I) is characterized by serum with very low or absent properdin activity in hemolytic assays and <0.1 μg/ml immunoreactive protein; type 2 (or II) is characterized by low but detectable levels of immunoreactive protein (»2 μg/ml) and impairment of some, but not all functional test, and type 3 (or III)- has normal levels of immunoreactive but dysfunctional protein. 10 Normal serum or plasma levels of properdin are variously quoted as about 5 or 25 µg/ml. Differences in properdin levels between healthy and diabetic persons (Chaudhry_B_2008)
Specifications
Product type Assays
Quantity 2 x 96 det.
Standard range 0.31 to 20 ng/ml
Detection level 0.31 ng/ml
Working volume 100 µl/well
Species Human
Cross reactivity Goat - No, Horse - No, Mouse - Yes, Pig - Yes, Rabbit - Weak, Rat - No, Sheep - No
Application The human Properdin ELISA kit is to be used for the in vitro quantitative determination of
human Properdin in serum, plasma, bronchoalveolar lavage fluid, urine and cerebrospinal
fluid samples.
Principle The human Properdin ELISA is a ready-to-use solid-phase enzyme-linked immunosorbent assay based on the sandwich principle with a working time of 3½ hours. The efficient format of a plate with twelve disposable 8-well strips allows free choice of batch size for the assay. Samples and standards are incubated in microtiter wells coated with antibodies recognizing human Properdin. Biotinylated tracer antibody will bind to the captured human Properdin. Streptavidin-peroxidase conjugate will bind to the biotinylated tracer antibody. Streptavidin-peroxidase conjugate will react with the substrate, tetramethylbenzidine (TMB). The enzyme reaction is stopped by the addition of oxalic acid. The absorbance at 450 nm is measured with a spectrophotometer. A standard curve is obtained by plotting the absorbance (linear) versus the corresponding concentrations of the human Properdin standards (log). The human Properdin concentration of samples, which are run concurrently with the standards, can be determined from the standard curve.
Storage and stability Product should be stored at 4 °C. Under recommended storage conditions, product is stable for at least six months.
Precautions For research use only. Not for use in or on humans or animals or for diagnostics. It is the responsibility of the user to comply with all local/state and Federal rules in the use of this product. Hycult Biotech is not responsible for any patent infringements that might result with the use or derivation of this product.
References 1. Harboe, M et al; The Role of Properdin in Zymosan- and Escherichia coli-Induced Complement Activation. J Immunol 2012, 189: 2606
Disease Autoimmunity
Applications
Application assays: The human Properdin ELISA kit is to be used for the in vitro quantitative determination of
human Properdin in serum, plasma, bronchoalveolar lavage fluid, urine and cerebrospinal
fluid samples.
Principle: The human Properdin ELISA is a ready-to-use solid-phase enzyme-linked immunosorbent assay based on the sandwich principle with a working time of 3½ hours. The efficient format of a plate with twelve disposable 8-well strips allows free choice of batch size for the assay. Samples and standards are incubated in microtiter wells coated with antibodies recognizing human Properdin. Biotinylated tracer antibody will bind to the captured human Properdin. Streptavidin-peroxidase conjugate will bind to the biotinylated tracer antibody. Streptavidin-peroxidase conjugate will react with the substrate, tetramethylbenzidine (TMB). The enzyme reaction is stopped by the addition of oxalic acid. The absorbance at 450 nm is measured with a spectrophotometer. A standard curve is obtained by plotting the absorbance (linear) versus the corresponding concentrations of the human Properdin standards (log). The human Properdin concentration of samples, which are run concurrently with the standards, can be determined from the standard curve.
References
Perfomance: The linearity of the assay was determined by serially diluting a serum. The line obtained a correlation coefficient of 0.9966
Recovery: Normal human blood samples (plasma) containing baseline levels of human Properdin, were spiked with human Properdin, in concentrations of 500 and 2000 ng/ml. Samples with and without human Properdin, were incubated for 1 hour at room temperature. Samples were measured using the ELISA. Values for human Properdin, ranged between 85.1% and 115.3%.
References
References: 1. Harboe, M et al; The Role of Properdin in Zymosan- and Escherichia coli-Induced Complement Activation. J Immunol 2012, 189: 2606
Assay Manual